Name: Switch_HV
Display Field: OBJECTID
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Service Item Id: c7877837b8d047acb79e50bbc5dc13e0
Copyright Text:
Default Visibility: false
MaxRecordCount: 1000
Supported Query Formats: JSON, geoJSON
Min Scale: 0.0
Max Scale: 0.0
Supports Advanced Queries: true
Supports Statistics: true
Has Labels: true
Can Modify Layer: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports Datum Transformation: true
Extent:
XMin: 604945.972012194
YMin: 2532279.58006095
XMax: 727443.992609475
YMax: 2622639.61189091
Spatial Reference: 32640
(32640)
LatestVCSWkid(0)
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: NORMALPOSITION
Field 2: null
Field 3: null
Field Delimiter: ,
Default Symbol: Style: esriSMSCircle
Color: [0, 97, 133, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
Default Label: <all other values>
UniqueValueInfos:
-
Value: 1
Label: Closed
Description:
Symbol:
-
Value: 2
Label: Not Applicable
Description:
Symbol:
-
Value: 0
Label: Open
Description:
Symbol:
Transparency: 0
Labeling Info:
Label Placement: esriServerPointLabelPlacementAboveRight
Label Expression: [NORMALPOSITION]
Use Coded Values: true
Symbol:
Color: [0, 0, 0, 255]
Background Color: N/A
Outline Color: N/A
Vertical Alignment: bottom
Horizontal Alignment: center
Right to Left: false
Angle: 0
XOffset: 0
YOffset: 0
Size: 8
Font Family: Arial
Font Style: normal
Font Weight: normal
Font Decoration: none
Min. Scale: 15.525055199843173
Max. Scale: 0.0
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: false
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: SubtypeCD
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID
)
-
SUBTYPECD
(
type: esriFieldTypeInteger, alias: Subtype
)
-
LOCATIONID
(
type: esriFieldTypeString, alias: Location ID, length: 64
)
-
OPERATINGVOLTAGE
(
type: esriFieldTypeInteger, alias: Operating Voltage
, Coded Values:
[240: 240 Volts]
, [415: 415 Volts]
, [11: 11 KV]
, ...2 more...
)
-
COMMISSIONNINGDATE
(
type: esriFieldTypeDate, alias: Commissionning Date, length: 8
)
-
STATUSINDICATOR
(
type: esriFieldTypeString, alias: Status Indicator, length: 25
, Coded Values:
[INSERV: In Service]
, [OUTSERV: Out of Service]
, [STANDBY: Standby]
, ...2 more...
)
-
PLANNINGSTATUS
(
type: esriFieldTypeString, alias: Planning Status, length: 12
, Coded Values:
[S: Suggested]
, [P: Proposed]
, [A: Approved]
, ...3 more...
)
-
CONTRACTNO
(
type: esriFieldTypeString, alias: Contract Number, length: 64
)
-
CONSULTANT
(
type: esriFieldTypeString, alias: Consultant, length: 64
, Coded Values:
[1: Energo Projekt]
, [2: Mott Macdonald]
, [3: Hamad Engineering Services]
, ...8 more...
)
-
CONTRACTOR
(
type: esriFieldTypeString, alias: Contractor, length: 64
, Coded Values:
[1: Al Badawi Tra. & Cont.]
, [2: Labib Trad. & Cont.]
, [3: Al Habib & Co. LLC]
, ...410 more...
)
-
REFERENCENO
(
type: esriFieldTypeString, alias: Reference Number, length: 100
)
-
LASTWORKORDERID
(
type: esriFieldTypeString, alias: Last Work Order ID, length: 32
)
-
LASTMAINTENANCEDATE
(
type: esriFieldTypeDate, alias: Last Maintenance Date, length: 8
)
-
NOMINALVOLTAGE
(
type: esriFieldTypeInteger, alias: Nominal Voltage
, Coded Values:
[240: 240 Volts]
, [415: 415 Volts]
, [433: 433 Volts]
, ...8 more...
)
-
HYPERLINK
(
type: esriFieldTypeString, alias: Hyper Link, length: 255
)
-
NORMALPOSITION
(
type: esriFieldTypeInteger, alias: Normal Position
, Coded Values:
[0: Open]
, [1: Closed]
, [2: Not Applicable]
)
-
MAXCONTINUOUSCURRENT
(
type: esriFieldTypeInteger, alias: Max Continuous Current
, Coded Values:
[2: 2 A]
, [50: 50 A]
, [100: 100 A]
, ...14 more...
)
-
MAXOPERATINGVOLTAGE
(
type: esriFieldTypeInteger, alias: Max Operating Voltage
, Coded Values:
[433: 433 V]
, [500: 500 V]
, [660: 660 V]
, ...18 more...
)
-
GROUNDRESISTANCE
(
type: esriFieldTypeDouble, alias: Ground Resistance
)
-
FUSEINDICATOR
(
type: esriFieldTypeString, alias: Fuse Indicator, length: 4
, Coded Values:
[N: No]
, [Y: Yes]
, [0: Null]
)
-
IMPULSEWITHSTANDVOLTAGE
(
type: esriFieldTypeDouble, alias: Impulse Withstand Voltage
)
-
THREESECRATINGKA
(
type: esriFieldTypeDouble, alias: 3 Second Rating KA
)
-
MAKINGCURRENTKAP
(
type: esriFieldTypeDouble, alias: Making Current in KAP
)
-
BREAKINGCURRENTKA
(
type: esriFieldTypeDouble, alias: Breaking Current in KA
)
-
EARTHSWITCH3SECRATINGKA
(
type: esriFieldTypeDouble, alias: Earth Switch 3 Second Rating KA
)
-
EARTHSWITCH3SECMAKINGCURKAP
(
type: esriFieldTypeDouble, alias: Earth Switch 3 s Making Current
)
-
PO_NUMBER
(
type: esriFieldTypeDouble, alias: PO Number
)
-
EAMSITEID
(
type: esriFieldTypeString, alias: EAM SIte ID, length: 50
)
-
JOBNUMBER
(
type: esriFieldTypeString, alias: JOBNUMBER, length: 20
)
-
CONNECTEDSUBSTATION
(
type: esriFieldTypeString, alias: Connected Substation, length: 70
)
-
CONNECTEDSWITCH
(
type: esriFieldTypeString, alias: Connected Switch, length: 70
)
-
MERGEKEY
(
type: esriFieldTypeString, alias: MERGEKEY, length: 30
)
-
GOVERNORATE
(
type: esriFieldTypeString, alias: GOVERNORATE, length: 50
)
-
DISTRICT
(
type: esriFieldTypeString, alias: DISTRICT, length: 50
)
Types:
ID: 6
Name: Oil Link Unit
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 2
Name: Overhead Load Break
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 4
Name: Ground Load Break
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 5
Name: Off Load Isolators
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 1
Name: Overhead Disconnect
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 3
Name: Ground Disconnect
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 7
Name: Earthing Switch
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 8
Name: 33 KV Drop Out Fuse Unit
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 9
Name: 11 KV Drop Out Fuse Unit
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 10
Name: 11 KV HFU Unit
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
ID: 11
Name: RMU Switch
Domains:
-
ANCILLARYROLE:
Inherited
-
ENABLED:
Inherited
-
OPERATINGVOLTAGE:
Inherited
-
PHASEDESIGNATION:
Inherited
-
MANUFACTURER:
Inherited
-
MANUFACTURINGYEAR:
Inherited
-
DATASOURCE:
Inherited
-
STATUSINDICATOR:
Inherited
-
PLANNINGSTATUS:
Inherited
-
CONSULTANT:
Inherited
-
CONTRACTOR:
Inherited
-
NOMINALVOLTAGE:
Inherited
-
NORMALPOSITION:
Inherited
-
MAXCONTINUOUSCURRENT:
Inherited
-
MAXOPERATINGVOLTAGE:
Inherited
-
GROUNDEDINDICATOR:
Inherited
-
INTERRUPTINGMEDIUM:
Inherited
-
MODEOFOPERATION:
Inherited
-
FUSEINDICATOR:
Inherited
-
EARTHFAULTINDICATOR:
Inherited
-
RATEDCURRENT:
Inherited
-
REMOTECONTROLLED:
Inherited
-
EAMCREATIONSTATE:
Inherited
Supported Operations:
Query
Query Attachments
Generate Renderer
Return Updates
Iteminfo
Thumbnail
Metadata